Diverse Hardware Infrastructure
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in front of the device. Industrial EMC protection makes MB5916A ready for every mission.
Security and Redundancy
MB5916A embeds OpenVPN and IPsec VPN, that allows you to tunnel your data securely throught the internet and prevent unauthorized control of your Serial Devices by malicious people. The integrated Rapid Spanning Tree Protocol (RSTP), allows you to add a backup Ethernet link in the event the primary one fails.
Switching between Modbus Protocols
Modbus Gateway supports the standard Modbus protocol and is capable of converting any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus ASCII for all supported hardware interfaces. All of this, in bidirectional mode: Ethernet and Serial ends can selected to be either master or slave.
Modbus ID Routing
Modbus Gateway supports various types of hardware communication interfaces, Modbus protocol conversion, and Modbus ID routing. Therefore the Modbus Gateway can integrate your existing and complex Modbus
hardware configuration into a simple network that can be easily managed.
Modbus Data Concentrator
The Modbus Data Concentrator performs pre-defined Modbus commands to read/write data from the slave devices via serial ports. It mirrors slave device data to its own memory. Therefore, requesting masters can receive response in a shorter period, achieving better overall efficiency.
Regular Modbus gateway
Modbus Concentrator
Environmental Limits | |
---|---|
Operating Temperature | -40°C~80°C (-40°F~176°F) |
Storage Temperature | -40°C~85°C (-40°F~185°F) |
Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
Physical Characteristics | Value |
---|---|
Housing | IP30 SPCC housing |
Dimension (W x H x D) | 440.6 x 44 x 309 mm (1U Rack-mount) |
Weight | 4,000g |
Installation | 19’’ Rack-Mount (Kit included) |
Reset Button | Yes |
Power | Value |
---|---|
Rated Supply Voltage | Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series) |
Input Voltage Range | Redundant 19.2-52.8 VDC or Redundant 85-264 VAC/ 100-370 VDC (HV Series) |
Input Current | 0.73 A @ 24 VDC 0.35 A @ 100 VAC 0.20 A @ 100 VDC |
Power Consumption | Approximately 20 W (Max) |
Connector | 10-Pin Terminal Block |
Power Redundancy | Yes |
Reverse Polarity Protection | Yes |
Software | |
---|---|
Protocols | IPv4, ICMP, TCP, UDP, DHCP Client, SNMPv1,v2c,v3, HTTP, HTTPS, Telnet, RFC2217, 802.1D-2004 RSTP, Security through OpenVPN Client/Server or IPsec VPN (peer-to-peer or peer-to-side) with up to 37.9Mbps VPN throughput, PPTP, and SMTP/TLS |
Configuration | Atop Management Utility, Web UI, Telnet |
VirtualCOM | Windows/Linux redirection software |
Modbus Gateway Supported Modes | Ethernet: Modbus TCP Server/Client(or VCOM); Serial: Modbus RTU/ASCII (master/slave) |
Maximum number of Modbus clients/slaves | Modbus TCP: Maximum 16 clients; Maximum 32 slave connections |
Modbus concentrator | Optional - please ask your ATOP Representative |
Modbus redundant concentrator | Optional - please ask your ATOP Representative |
Serial Interface | |
---|---|
Connector | D-Sub9 (DB models, supporting only 5-pin RS-232 mode) or 5.08mm 5-Pin Terminal block (TB Models) |
Ports | 16 |
Mode | RS-232/422/485 Software selectable |
Serial Isolation | 3 kV (Sis versions only) |
Baud Rate | 1,200 ~ 921,600 bps software selectable |
Data Bits | 5, 6, 7, 8 software selectable |
Stop Bits | 1, 2 software selectable |
Flow Control | None, Xon/Xoff, RTS/CTS |
Network Interface | |
---|---|
Speed | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) - RJ45 version IEEE 802.3u 100Base-FX - SFP version |
Network mode | Independent IP address (6 ports) or Independent IP address (4 ports) + Unmanaged Switch (3 ports, including LAN4) |
Connector ports | RJ45 x 6 (RJ45 version) SFP x 6 (SFP version) |
Certification | Standard |
---|---|
Shock Drop (Freefall) Vibration | MIL-STD-810F Method 516.5 MIL-STD-810F Method 516.5 MIL-STD-810F Method 514.5 C1 & C2 |
RoHS | Yes |
MTBF | MB5916A-6SFP-Sis-HV: 9.18 years; MB5916A-6SFP-Sis: 8.63 years |
Warranty | 5 years |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge Air Discharge | ±8kV ±15kV | 4 |
IEC 61000-4-3 | RS | Radiated (enclosure) | 20 V/m | 3 |
IEC 61000-4-4 | EFT | AC Power Port DC Power Port Signal Port | ±4.0kV | 4 |
IEC 61000-4-5 | Surge | AC Power Port AC Power Port DC Power Port DC Power Port Signal Port | Line-to Line±2.0KV Line-to Earth±4.0KV Line-to Line±1.0KV Line-to Earth±2.0KV Line-to Earth±4.0KV | 4 4 3 3 4 |
IEC 61000-4-6 | CS | AC Power Port DC Power Port Signal Port | 10 V rms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 100 A/m 1000 A/m (1sec.) | 5 6 |
IEC 61000-4-11 | DIP | AC Power Port | 30% reduction (Voltage Dips), 1 period 60% reduction (Voltage Dips), 50 period 100%, reduction (Voltage interruptions), 5 period 100% reduction (Voltage interruptions), 50 period | - |
Certification | Standard |
---|---|
Safety | EN61010-1, EN 61010-2-201 |
EMC | FCC Part 15, Subpart B, Class A, EN 55032, Class A, EN 61000-6-2, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613 |
MODEL NAME | PART NUMBER | DESCRIPTION |
---|---|---|
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
GDC-120 | 59906861G | 120mm copper woven grounding cable |
ADP-DB9(F)-TB5 | 59906231G | Female DB9 to Female 3.81 TB5 Converter |
AXFD-1314-0523 | 522AXFD1314011G | SFP Transceiver;155Mbps, Multi-mode;1310nm;2km;-40~85, DDMI |
AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver;155Mbps, Single-mode;1310nm;30km;-40~85, DDMI |
MODEL NAME | PART NUMBER | DESCRIPTION | ETHERNET PORTS | SERIAL PORTS |
---|---|---|---|---|
MB5916A CT | Contact ATOP headquarters | Industrial 16-Port Modbus Concentrator, DB9(M), RS-232/422/485, RJ45, dual pwr input | 6 (RJ45) | 8 (DB9) |
MB5916A-TB CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, RJ45, dual pwr input | 6 (RJ45) | 8 (TB5) | |
MB5916A-Sis CT | Block, RS-232/422/485, 3kV Isolation, RJ45, dual | 6 (RJ45) | 8 (TB5) | |
MB5916A-6SFP CT | Industrial 16-Port Modbus Concentrator, DB9(M), RS-232/422/485, SFP, dual pwr input | 6 (SFP) | 8 (DB9) | |
MB5916A-6SFP-TB CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, SFP, dual pwr input | 6 (SFP) | 8 (TB5) | |
MB5916A-6SFP-Sis CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, 3kV Isolation, SFP, dual pwr | 6 (SFP) | 8 (TB5) | |
MB5916A-HV CT | Industrial 16-Port Modbus Concentrator, DB9(M), RS-232/422/485, RJ45, dual pwr input | 6 (RJ45) | 16 (DB9) | |
MB5916A-TB-HV CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, RJ45, dual pwr input | 6 (RJ45) | 16 (TB5) | |
MB5916A-Sis-HV CT | Block, RS-232/422/485, 3kV Isolation, RJ45, dual | 6 (RJ45) | 16 (TB5) | |
MB5916A-6SFP-HV CT | Industrial 16-Port Modbus Concentrator, DB9(M), RS-232/422/485, SFP, dual pwr input | 6 (SFP) | 16 (DB9) | |
MB5916A-6SFP-TB-HV CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, SFP, dual pwr input | 6 (SFP) | 16 (TB5) | |
MB5916A-6SFP-Sis-HV CT | Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, 3kV Isolation, SFP, dual pwr | 6 (SFP) | 16 (TB5) |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.71 | MB59xx CT Firmware | 2023-08-21 | 16.3 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.1 | Datasheet EN | 2023-08-25 | 514.64 KB | |
v1.2 | Datasheet EN | 2023-11-03 | 458.54 KB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.5 | MB59XX CT User Manual | 2023-08-21 | 5.44 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.3 | SE5908-SE5916A-MB5908A-MB5916A-PG5900A-PG5908A-PG5916A Hardware Installation Guide | 2023-08-21 | 4.39 MB |