NTS8600

Advanced SyncPro: IEC61850-3 HV & IEEE 1613 Certified NTP Server & IEEE 1588 PTP Grandmaster

  • IEC 61850-3 HV & IEEE 1613 Certified NTP Server & IEEE 1588 PTP Grandmaster
  • -40 to +85 °C Operating Temperature, IP30 Protection, and Up to 5100 m Altitude
  • MIL-STD-810F Certified for Environmental and Transportation Reliability
  • Dual Power Inputs: DC (Built-in) or AC (via Adapter) with Wide Input Range
  • Full Redundancy Across Power, System, Network, and Link Layers
  • <40 ns PRTC-B/PTP, <50 μs NTP Accuracy, Calnex Verified
  • Excellent Holdover Performance: <0.5 μs/8 Hours / <72 μs/7 Days
  • Supports Power, Telecom, AVBTSN and Enterprise Profile
  • Three Ethernet Ports: Two PTP-Capable Combo Ports, All Three NTP-Capable
  • Supports Power, Telecom Profiles, AVBTSN and Media Broadcast Profiles
  • Dual Media Combo Ports Enable Cost-Effective Copper/Fiber Deployment
  • Supports Multi-Constellation GNSS with Anti-Jamming and Anti-Spoofing
  • Antenna Fault Detection and Protection: Short Circuit and Disconnection
  • Configurable IRIG-B (TTL, AM, RS-485), PPS, and 10 MHz Outputs
  • Compact design with rackmount and DIN-rail installation options
  • Standard 5-Year Warranty, Upgradeable to 10 Years
New
NTS8600

IEC 61850-3 HV & IEEE 1613 Certified NTP/PTP Grandmaster with -40 to +85 °C Operating Temperature

With an operating temperature range of -40 to +85 °C, and IEC 61850-3 HV and IEEE 1613 offering up to four times the EMC protection compared to rugged industrial-grade standards, the NTS8600 is engineered to operate reliably in environments exposed to electrical noise, temperature extremes, and radiated disturbances—ensuring uninterrupted performance and high system availability. The NTS8600 NTP Server and IEEE 1588 PTP Grandmaster is the world’s first solution fully certified to both IEC 61850-3 HV and IEEE 1613 standards, delivering exceptional resilience and precision in demanding applications such as power substations, telecommunications networks, automation systems, and enterprise infrastructure.

 

High Precision Timing

Rigorously tested by Calnex Solutions,  a leader in network synchronization testing, the NTS8600 series delivers exceptional time precision, ensuring your power applications’ synchronization needs are met with the highest standards of accuracy. Featuring proven PRTC-B accuracy within 40 ns, IEEE 1588 PTP accuracy within 40 ns, and NTP accuracy within 50 μs, this Grandmaster guarantees precise time distribution across your network.

 

 

Superior Holdover Performance

Holdover performance is critical to ensure uninterrupted and accurate time synchronization during loss of the primary time source. The NTS8600 series offers exceptional holdover stability, with a drift of less than 0.5 μs over 8 hours, and approximately 72 μs over 7 days, as validated by Calnex Solutions. When entering holdover mode, the system intelligently adjusts protocol attributes according to the active time profile (e.g., Power, Telecom), and proactively issues notifications via alarms and syslog to alert operators.

 

Versatile Profile Support and Upgradeability

The Grandmaster supports a wide range of IEEE 1588 PTP profiles, making it suitable for deployment in power, telecom, AVB/TSN, and enterprise networks. For power utilities, it complies with IEEE C37.238-2011, C37.238-2017, and IEC/IEEE 61850-9-3:2016. Telecom synchronization is supported through ITU-T G.8265.1, G.8275.1, and G.8275.2 profiles. IEEE 802.1AS is also supported for time-sensitive networking in industrial and media environments. The Enterprise profile ensures interoperability across standard IT infrastructures. In addition, the Grandmaster supports SyncE for enhanced frequency stability in telecom applications.

 

GNSS Vulnerability Mitigation and Antenna Protection

NTS8600 offers enhanced robustness and resilience against jamming and spoofing attacks. By receiving signals from multiple constellations for verification, the system can provide spoofing detection and enter holdover mode if necessary. The Grandmaster also features comprehensive antenna vulnerability mitigation, detecting short and disconnected antennas to maintain system integrity. For added protection, a surge protector is available for purchase, safeguarding your equipment from electrical surges and ensuring the reliability of your timing infrastructure.

 

Comprehensive Redundancy

System redundancy is guaranteed by clustering featuring IEC 62439-3 Parallel Redundancy Protocol (PRP) to ensure network redundancy without data loss or downtime. Link redundancy is achieved through bonding, providing resilient connectivity. Additionally, NTS8600 series offers power redundancy options, including dual DC inputs or a combination of one DC and an external HVAC/HVDC power supply, to safeguard against power failures.

 

 

Flexible Timing Output

Modulated IRIG-B is ideal for long-distance transmission due to its resistance to signal degradation and compatibility with legacy equipment. Demodulated IRIG-B, available in TTL or RS-485 formats, offers higher precision, with IRIG-B RS-485 supporting distances up to 1200 meters. PPS and 10MHz outputs are crucial timing signals in modern IEC 61850 power applications, providing precise synchronization essential for various grid operations. The NTS8600 series features up to six configurable outputs, including IRIG-B TTL, AM, RS-485, 1-PPS, and 10MHz waveform. Additionally, IRIG-B RS-485 can be extended over long distances using the ATOP SF63 serial-to-fiber converter via fiber-optic cable.

 

Ensuring Precision with Comprehensive Delay Compensation

Compensation for antenna delay is essential because long antenna cables can introduce timing errors that affect the accuracy of synchronized operations. Similarly, output delay compensation for signals such as IRIG-B and PPS is vital, especially in systems with multiple IEDs connected. It is much easier and more efficient to compensate for cable delays at the Grandmaster level rather than at each individual IED, as not all IEDs support delay compensation. Handling these adjustments centrally at the Grandmaster guarantees that all connected devices operate in perfect sync, optimizing the performance and coordination of critical substation operations.

 

APPLICATION CASE

IEEE 1588 in Power Networks: Precision Time Synchronization and Time Redundancy
Two NTS8600 units in the station layer determine the Active and Backup GMC through BMCA. The Active GMC synchronizes to both GPS and GNSS satellite systems and transmits via IEC 62439-3 PRP to two power domains composed of PRP and HSR networks.
According to IEC 61850-9-3 and IEEE C37.238-2017, the total end-to-end budget is 1us, with GMC being 250ns. The NTS8600 achieves superior accuracy of <40ns, reserving more budget for other devices. For early MU devices that rely on 1PPS or IRIG-B for synchronization, the NTS8600 offers 1PPS, IRIG-TTL, IRIG-B AM, IRIG-B RS-485, and RS-485 to fiber-optics by SF-63 for long-distance transmission and delay compensation.
The HSR network provides zero-packet-loss redundancy but also increases latency. Devices in the process layer require more precise timing. When the end-to-end budget cannot be met, a GMC must be deployed to aid in accurate timing for critical devices. The NTS8600, certified to IEC 61850-3 HV & IEEE 1613, operates reliably in harsh process layer environments, providing precise synchronization.
In addition to the NTS8600, our timing solution for power substations also includes BC or TC of RHG9728 and RHG9528, P-Delay TC of EH9711, HSR Redbox, and Quadbox of RGB700X. Check our website for more detailed information on these products

 

 

CONNECTORS

Technical Specifications 
Model NameNTS8600/NTS8600I Series
GNSS Receiver Specifications
GNSS Input ports1x GNSS Input; SMA (F) - active Antenna
GNSS Module specific InformationMulti-Constellation Supported: GPS L1, GLONASS L1, BeiDou B1, Galileo E1
Maximum Concurrent Constellations: 3
Leap Second: Supported
Sensitivity for GPS:
• Tracking: -166 dBm
• Reacquisition: -160 dBm
• Cold Start: -148 dBm
• Hot Start: -160 dBm
Acquisition TimesCold Start: <45 seconds
Warm Start: <7 seconds
Antenna Requirements3.3 V, <50 mA
Minimum gain=5dB; Maximum gain + Cable Attenuation ≤ 40dB
GNSS Vulnerability MitigationJammingSupport Detection, Warning and Switch to OCXO
Holdover
SpoofingSupport Detection, Warning and Switch to OCXO
Holdover (GNSS Antenna Only)
Antenna Vulnerability
Mitigation
Antenna Cable ShortSupport Detection, Warning and Switch to OCXO
Holdover Mode
Antenna DisconnectionSupport Detection, Warning and Switch to OCXO
Holdover Mode
Antenna specification (Accessories) 
GNSS Antenna
(70100000000090G)
GNSS receiver: GPS L1, GLONASS L1, BeiDou B1, Galileo E1
LNA Gain: 40dB min
Weather-Proof Housing: IP69K
Operating and Storage Temperature: -40°C ~85°C
ESD: ±15KV Air Discharge
Mechanical size: 66.5 mm dia. x 21 mm H
MIL-STD-810F
Supply Voltage Range: 2.5 to 16VDC
GPS Antenna
(70100000000091G)
GNSS receiver: GPS L1, Galileo E1
LNA Gain: 40dB min
Weather-Proof Housing: IP69K
Operating and Storage Temperature: -40°C ~85°C
ESD: ±15KV Air Discharge
Mechanical size: 66.5 mm dia. x 21 mm H
MIL-STD-810F
Supply Voltage Range: 2.5 to 16VDC
Anti-Jamming GNSS Antenna
(70100000000098G)
GNSS Receiver: GPS L1, GLONASS L1, BeiDou B1, Galileo E1
LNA Gain: 40dB typ.
Weather-Proof Housing: IP67
Operating and Storage Temperature: -40°C - 85°C
ESD: ±15KV Air Discharge
Mechanical Size: 100 mm dia. x 102 mm H
MIL-STD-810F
Supply Voltage Range: 2.5 to 16VDC
Maximum Antenna Cable LengthAntenna cable:
Without amplifier:
LMR-400: 150M CFD-200: 50M RG58A/U: 25M
With Amplifier:
LMR-400: 250M CFD-200: 80M RG58A/U: 50M
Maximum Sync-Out Cable LengthRG58 A/U Sync-Out cable:
1PPS, 10MHz, IRIG-B TTL: 150M
IRIG-B AM: 150M @ 1K impedance , 300M @ 10K impedance
IRIG-B RS485: 1200M
IRIG-B RS-485 with SF63 Fiber optic 2KM
Proven Clock Accuracy (Relative to UTC)
1PPS±40 ns Peak *1
Demodulated IRIG-B±40 ns Peak *1
Modulated IRIG-B AM±1 μs Peak *1
RS-485 IRIG-B±100 ns Peak *1
PTP Timestamp±40 ns Peak *1
NTP Timestamp±50 us Peak , ±40 us Average *1
Holdover accuracy - OCXO<0.5 us / 8 hours / <72 us / 7 days *2
*1. Device locked to satellites for at least 24 hours.
*2. Device locked to satellites for at least 48 hours before holdover
Network Interface 
Ethernet StandardsIEEE 802.3 10BaseT
IEEE 802.3u 100BaseT(X)
IEEE 802.3ab for 1000BaseT(X) IEEE 802.3u for 100Base-FX IEEE 802.3z for
1000Base-X
Gigabit Ethernet PortsTwo Combo ports, 2x 10/100/1000BASE-T(X) RJ45 or 2x 100/1000 Base-X SFP
Support Synchronous Ethernet (SyncE) per ITU-T G.8261 ITU-T, G.8262 and G.8264
ESMC), PTP-Capable and NTP-Capable
Management Port1x 10/100 BASE-T(X) RJ45, NTP-Capable
I/O 
Console1x DB9 Serial Console Port
SD slot1x micro-SD slot
Relay - Alarm ContactRated Operational Voltage: 24 VDC
Continuous carrier: 1A
Normal Open
Pickup time: 2.5ms
Turn-off time: 1ms
Sync-Out 
Standard Sync-Out
(Sync 1, Sync 2)
Two configurable output channels (coaxial BNC (F) connector):
1. 10MHz (Square Wave)
2. 1PPS/PPM/PPH Output (Square Wave, configurable pulse width)
3. IRIG-B TTL (Support IEEE1344 and C37.118.1)
4. AFNOR French Time Code
5. BCD, BJT, ST and ST Checksum (Contact sales for these timecodes)
Extend Sync-Out (NTS8600I)
(Sync 3 ~ Sync 6)
Three extra configurable output channels
(Sync 3 ~ Sync 5, coaxial BNC (F) connector):
1. 10MHz (Square Wave)
2. 1PPS/PPM/PPH Output (Square Wave, configurable pulse width)
3. IRIG-B TTL B000~B007 (Support IEEE1344 and C37.118.1)
4. IRIG-B AM B120~B127 (Support IEEE1344 and C37.118.1)
5. AFNOR French Time Code
6. BCD, BJT, ST and ST Checksum (Contact sales for these timecodes)
One extra standalone channel (Sync 6, TB3 connector)
1. IRIG-B RS-485 B000~B007 (Support IEEE1344 and C37.118.1)
Electrical Output Drive Levels
1PPS5VDC 20 mA TTL compliant
IRIG-B TTL5VDC 20 mA TTL compliant
Modulated IRIG-B5Vp-p, 3.3:1 ratio, AM, Sinewave
IRIG-B RS485±5 VDC IRIG-B Half-Duplex; 32 Transceivers Max. a bus
Frequency 
OscillatorAdvanced managed OCXO, with temperature drifting compensation
IEEE1588 Profiles 
DefaultIEEE 1588V2 (PTPv2)
Default UDP (IEEE1588-2008 Annex D and J)
Default 802.3 (IEEE1588-2008 Annex F and J)
PowerIEC/IEEE61850-9-3-2016 Power Utility Profile
IEEE C37.238-2011 Power Profile, with VLAN support
IEEE C37.238-2017 Power Profile, with VLAN support
TelecomITUT-G.8265.1 Frequency
ITUT-G.8275.1 Phase/Time
ITUT-G.8275.2 Phase/Time
AVBTSN802.1AS Profile
EnterpriseEnterprise Profile
*Media Broadcast
(In Development Plan)
SMPTE ST 2059-2
AES67 Media Profile
System Modes 
GNSS Locked ModeSynchronizes time with GNSS signals for high accuracy
Holdover ModeMaintains time using the OCXO clock after GNSS is unavailable
Free Run ModeOperates independently using RTC as the time source along with the OCXO clock
Functions & Protocols
ProtocolsNetwork
Synchronization
RFC 1119 (NTPv2) Server
RFC 1305 (NTPv3) Server
RFC 5905 (NTPv4) Server
RFC 1769 (SNTPv3) Server
RFC 2030 (SNTPv4) Server
Network ProtocolsVLAN (IEEE 802.1q) filtering/tagging
IEEE 802.1p QoS
DSCP
IPv4, IPv6
TCP, UDP
DHCP Client
TACAS+/ RADIUS
RedundancyDevices Clustering (NTP Only)
PRP (IEC 62439-3)
Bonding – Active & Backup
Bonding -- LACP
Combo Ports
ManagementHTTP, HTTPS
SNMP v1/v2,v3
SSH/ Telnet (CLI), could be enabled/disabled
Console CLI
Estimated Time Accuracy
GNSS Status
Power Status
PTP & NTP Status
SD/MMC Backup & Restore
Event & AlarmEvent Log
Syslog
Relay & Alarm Management
SNMP Trap
Physical Characteristics
HousingSPCC w/Zinc Plated Body + Aluminum cover
IP30 Metal Housing
Dimension (W x H x D)252.8 x 220 x 44
Weight2KG (AC + IRIG-B) / 1,9KG (DC + IRIG-B)
Installation1U Rack-mountable or DIN-Rail Kits (Optional)
Power Supply 
Rated Supply Voltage110 – 240 VAC, 50/60HZ (NTS8600 AC series)
110 – 250 VDC (NTS8600 AC series)
24 – 60 VDC (NTS8600 DC series)
Input Voltage Range85 – 264 VAC, 50/60 HZ (AC series)
88 – 300 VDC, (AC series)
19 – 66 VDC, (DC series)
Power ConsumptionApproximately 9.4 W (Max)
Environmental Limits
Operating Temperature-40°C to +85°C (-40°F to 185°F)
Storage Temperature-40°C to +85°C (-40°F to 185°F)
Operating Altitude5100m
Ambient Relative Humidity5% to 95% (Non-condensing)
Regulatory Approvals 
SafetyUL 62368-1 , CB IEC62368-1/EN62368-1 (UL Certified Operating Temperature: 75°C)
EMCFCC(EMI): FCC Part 15, Subpart B, Class A
CE(EMI): EN 55032, EN61000-6-4, Class A
EN 61000-3-2 (Current Harmonics)
EN 61000-3-3 (Voltage Flicker)
CE(EMS): EN 55035, EN61000-6-2
CE(GNSS): EN 303 413. EN 301 489-19
Power AutomationIEC61850-3, IEEE 1613
TestItemTestValueLevel
IEC 61000-4-2ESDContact Discharge
Air Discharge
±8KV
±15KV
4
4
IEC 61000-4-3RSEnclosure Port10(V/m), 80-3000MHz
20(V/m), 80-1000MHz
3
IEC 61000-4-4EFTAC Power Port
DC Power Port
Signal Port
±4.0KV
±4.0KV
±2.0KV
4
4
Special
IEC 61000-4-5SurgeAC Power Port
AC Power Port
DC Power Port
DC Power Port
Signal Port
Line-to Line±2.0kV
Line-to Earth±4.0kV
Line-to Line±1.0kV
Line-to Earth±2.0kV
Line-to Earth±4.0kV
4
4
4
3
4
IEC 61000-4-6CS0.15-80MHz10V rms 0.15-80MHz, 80% AM3
IEC 61000-4-8PFMF(Enclosure)100A/m continuous, 1000A/m (3s)5
IEC 61000-4-11DIPAC Power Port30% reduction (Voltage Dips), 1 period
60% reduction (Voltage Dips), 50 period
100%, reduction (Voltage interruptions),
5 period
100% reduction (Voltage interruptions),
50 period
-
IEC 61000-4-16Main Frequency
Voltage
DC Input Port
Signal Port
30V Continuous, 300V 1s
30V Continuous, 300V 1s
4
4
IEC 61000-4-17RippleDC Input Port10% of unit3
IEC 61000-4-18Damped
Oscillatory
AC Power Port2.5KV common,
1KV differential mode @ 1MHz
3
Signal Port Telecommunication
Port
2.5KV common,
1KV differential mode @ 1MHz
3
IEC 61000-4-29DC Voltage Dips
& Interruptions
DC Input Port30% Reduction (Voltage Dips):0.1 sec
60% Reduction (Voltage Dips):0.1 sec
100% Reduction
(Voltage Interruption):0.05 sec
-
CertificationStandard
Shock
Drop
Vibration
MIL-STD-810G Method 516.5
MIL-STD-810F Method 516.5
MIL-STD-810F Method 514.5 C-1 & C-2
RoHS2Yes
MTBF20 years
Warranty5 years / Upgradable to 10 years

Main core and Modules of NTS8600

Model NamePart NumberEthernet PortSync-OutInput Voltage Range
NTS8600-DC1P1NTS86000001G1 x 10/100
MGMT RJ45 port
and 2 x 10/100/1000
RJ45/SFP combo ports
Standard Sync-Out
(Total Sync-Out
Channels: 2)
Dual 19-66 VDC
NTS8600-AC1P1NTS86000002GSingle 85-264 VAC or
88-300 VDC
NTS8600I-DC1P1NTS8600I001GExtend Sync-Out
(Total Sync-Out
Channels: 6)
Dual 19-66 VDC
NTS8600I-AC1P1NTS8600I002GSingle 85-264 VAC or
88-300 VDC
* NTS8600 Dual AC input can be achieved using two external SDR-75-24 power supplies
or by selecting the NTS8600 model.

Optional Accessories – Antenna, Amplifier, Surge Protector and Mounting Kits

Model NamePart NumberDescription
GNSS Antenna
Package
70100000000090GThis package includes:
1. High Gain Multi-Constellation TNC-Female Antenna
(See the Antenna Specifications section above for a spec summary)
2. 2 meters SMA Male to TNC Male antenna cable
GPS Antenna
Package
70100000000091GThis package includes:
1. High Gain GPS L1 TNC-Female Antenna
(See the Antenna Specifications section above for a spec summary)
2. 2 meters SMA Male to TNC Male antenna cable
Anti-Jamming GNSS
Antenna
70100000000098GThis package includes:
1. High Gain Anti-Jamming Multi-Constellation TNC-Female Antenna
(See the Antenna Specifications section above for a spec summary)
2. 2 meters SMA Male to TNC Male antenna cable
RF Amplifier70100000000092GInline TNC-Female RF (1559-1610MHz) Amplifier
25dB with supply volts 3-10 VDC and 10mA
Surge Protector70100000000093GSOCAA 4LTJ10TP001 – TNC-Female to TNC-Male
10KA Surge protection device
Advanced Surge
Protector
70100000000094GPhoenix Contact CN-UB-280DC-BB – N-Type 20 KA Surge protection
device including one N-type Male to TNC Male adapter and one N-type
Male to TNC Female
Mounting Kits70100000000095GThe antenna mounting kit includes an L-bracket, mount adapter and
ground plane. (See NTS8600 Accessories Guide for more details)

Optional Accessories – Antenna and Sync-Out Cables

Model NamePart NumberDescription
Antenna Cable 20M RG58 A/U50802151GTNC-Male to TNC-Female 20 Meters RG58 A/U Antenna Cable
Antenna Cable 30M CFD-20050802161GTNC-Male to TNC-Female 30 Meters CFD-200 Antenna Cable
Antenna Cable Custom-Length CFD-200Made to OrderTNC-Male to TNC-Male Custom-Length CFD-200 Antenna Cable.
Specify desired length when ordering. Supports up to 50 m without
amplifier, or 80 m with amplifier.
Antenna Cable Custom-Length LMR-400Made to OrderTNC-Male to TNC-Male Custom-Length CFD-200 Antenna Cable.
Specify desired length when ordering. Supports up to 150 m without
amplifier, or 250 m with amplifier.
Sync-Out Cable (IRIG-B/PPS TTL)Made to OrderBNC-Male to BNC-Male Custom-Length RG58 A/U Antenna Cable.
Specify desired length when ordering. Supports up to 150 m.

Optional Accessories – SFP Modules

Model NamePart NumberDescription
AXFD-1314-0523522AXFD1314001GSFP Transceiver, 155Mbps, 1310nm, Multi-mode, 2km,
-40°C to +85°C, DDMI
AXFD-1314-0553522AXFD1314011GSFP Transceiver, 155Mbps, 1310nm, Single-mode, 30km,
-40°C to +85°C, DDMI
AXGD-5854-0513522AXGD5854001GSFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V,
-40°C to +85°C, DDMI
AXGD-1354-0523522AXGD1354001GSFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V,
-40°C to +85°C, DDMI
AXGD-1354-0533522AXGD1354011GSFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V,
-40°C to +85°C, DDMI
AXGD-3354-0593522AXGD3354001GSFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V,
-40°C to +85°C, DDMI

Optional Accessories – External Power Adapter and Converter

Model NamePart NumberDescription
SDR-75-2450500752240001GDIN RAIL POWER SUPPLY / T; 88~264VAC/
124~370VDC to 24VDC 3.2A; 75W
SF63 SeriesSee ATOP SF63 DatasheetIndustrial Serial to Fiber Media Converter for long distance transmission

Firmware

Version Name Time Size Download
v1.07 NTS8600 Series Firmware(compatible with MIB v102) 2025-06-13 20.7 MB
v1.06 NTS8600 Series Firmware(compatible with MIB v101) 2025-06-13 20.66 MB
v1.05 NTS8600 Series Firmware 2025-05-05 20.63 MB
v1.04 NTS8600 Series Firmware 2025-03-24 20.2 MB
v1.03 NTS8600 Series Firmware 2024-11-26 19.98 MB

Datasheet

Version Name Time Size Download
v1.6 NTS8600 Series Datasheet EN 2025-08-12 811.66 KB

Manual

Version Name Time Size Download
v1.02 NTS8600 Series User Manual 2025-06-20 5.74 MB
v1.01 NTS8600 Series User Manual 2025-05-05 5.73 MB
v1.0 NTS8600 Series User Manual 2024-11-26 5.39 MB

Hardware Installation Guide

Version Name Time Size Download
v1.1 NTS8600 Series Hardware Installation Guide 2025-02-11 715.18 KB

MIB

Version Name Time Size Download
v102 NTS8600 Series MIB(compatible with FW v1.07) 2025-06-13 15.54 KB
v101 NTS8600 Series MIB(compatible with FW v1.06) 2025-06-13 15.57 KB
v100 NTS8600 Series MIB 2025-05-05 14.94 KB

STP/DXF drawings

Version Name Time Size Download
NTS8600 Series STP file 2024-11-26 26.56 MB

Test reports

Version Name Time Size Download
NTS8600 Series CB 62368-1 Certification 2024-11-26 245.18 KB
NTS8600 Series CE EMC Certification 2024-11-26 13.56 MB
NTS8600 Series CE RF Certification 2024-11-26 9.2 MB
NTS8600 Series FCC Certification 2024-11-26 2.56 MB
NTS8600 Series IEC 61850-3&IEEE1613 2024-11-26 13.17 MB
NTS8600 Series UL Cerficaite 2024-11-26 477.43 KB

I have read and agree to the Privacy Policy (art.13 and 14 of the GDPR - EU Regulation 2016/679).